Fluke - 3130-G2M Portable Pressure Calibrator

The 3130-G2M Portable Pneumatic Pressure Calibrator is ideal for calibrating pressure transmitters, transducers, gauges and similar devices. The 3130-G2M contains everything you need to generate, control and measure pressure, as well as read the output of the device under test (DUT).
Features
  • Measure and generate pressures from vacuum to 2 MPa (300 psi, 20 bar)
  • Internal pump can generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar)
  • Supply pressure connection allowing the use of external gas supply up to 2 MPa (300 psi, 20 bar)
  • Includes variable volume for fine adjustment of pressures
  • Pressure measurement accuracy of 0.025% reading ±0.01% FS
  • Electrical measurement and 24 volt supply for close looped calibrations
  • Measure or generate 4 to 20 mA
  • Measure 0 to 30 V DC
  • Powered by internal, high capacity, NiMH battery or universal ac mains adapter
  • Compatible with Fluke 700P Pressure Modules

Fluke - 700G Pressure Gauge Calibrator

  • Rugged, high-quality pressure gauge calibrator for fast and accurate test results
  • Delivers precision pressure measurements in 23 ranges from ±10 inH2O/20 mbar to 10,000 psi/690 bar
  • Delivers high accuracy—0.05% total measurement uncertainty for one year
  • Provides bright backlit display for easy viewing
  • Features rugged, durable design with protective holster

Fluke - 717 Pressure Calibrator

  • Measure pressure, 0.05% of full scale with internal sensor up to 5000 psi/345 bar sensor (5000G model)
  • Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24 V loop power
  • Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules
  • 1/8 NPT female pressure fitting
  • Compatible with non-corrosive Gases and liquids
  • Select eleven different engineering units
  • Zero, min, max, and hold functions
  • Calibrate P/I instruments with simultaneous pressure and current measurement
  • Pressure switch test function captures set, reset and Deadband values of a pressure switch
  • Error % calculation of mA measurements for quick pass-fail decisions
  • Long lasting battery life
  • Holster features test lead storage
  • Compatible with Toolpack magnetic hanging system
  • New switch test

Fluke - 718 Pressure Calibrator

  • Pressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device
  • Integrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field
  • Error % calculation for quicker pass/fail decision making in the field
  • Best in class mA accuracy of 0.015% for better measurement confidence and workload coverage
  • Min/Max/Hold to capture changing measurements
  • Switch test feature for quicker and more accurate pressure switch testing
  • New 1 and 300 psi pressure ranges mean fewer extra tools required
  • 1, 30, 100 & 300 psi ranges now available

Fluke - 718Ex Intrinsically Safe Pressure Calibrator

  • ATEX II 1G Ex ia IIC T4 Compliant.
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Wide range of selectable measurement units for pressure.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.
  • Pressure switch test function.
  • Min-Max Hold functions.
  • Compact size and weight.
  • Simple, push-button user interface.
  • Rugged and reliable, ideal for field use.

Fluke - 719 Pressure Calibrator

  • Pressure calibrator with built-in electric pump for one-handed pressure calibration
  • Offers best-in-class pressure measurement uncertainty of 0.025%
  • Measures and sources mA with best in class 0.015% accuracy to test valves and I/Ps
  • Calibrates 30 psi and 100 psi pressure ranges
  • Features precision pressure adjustment vernier for easy and accurate pressure calibration

Fluke - 719 Pro Electric Pressure Calibrator

  • Unique integrated electric pump for one handed pressure calibration
  • Test pressure switches easily with easy-to-use switch test function
  • Precision pressure adjust vernier for easy and accurate pressure calibration
  • Ideal accuracy and performance (0.025%) for reference class transmitter calibration
  • 30 psi, 150 psi and 300 psi pressure ranges
  • Programmable pressure calibrator pump limit:
    • Eliminates over-pressurization
    • Allows the user to program target pressures for pumping
  • Extended pressure measurement range with any of 29 750P Pressure Modules
  • Pump cleanout ports reduce pump failures from moisture and fluid damage
  • Fluid trap included with the unit to mitigate chance of fluid damage in at-risk applications
  • Precision temperature measurement with optional RTD probe

Fluke - 721 Pressure Calibration Instruments

  • Precision pressure calibrator with dual isolated sensors for gas flow calibration (custody transfer) applications
  • Features two isolated, stainless steel, pressure sensors with 0.025% accuracy
  • Includes Pt100 RTD input for temperature measurement (probe optional)
  • Measures 4 to 20 mA signals
  • Provides internal 24 V loop power supply to power a transmitter under test

Fluke - 725 Multifunction Process Calibrator

  • Powerful, easy-to-use field calibrator
  • Measures volts, mA, pressure, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters
  • Sources/simulates volts dc, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Measures/sources pressure using any of 50 Fluke 750P Pressure Modules
  • Easy to read measure/source screen displays input and output simultaneously

Fluke - 725Ex Series Process Calibrator

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

Fluke - 726 Precision Multifunction Calibrators

  • Precision multifunction process calibrator designed specifically for the process industry
  • Delivers precise measurement and calibration source performance with accuracies of 0.01%.
  • Stores up to eight calibration results in memory for later analysis
  • Offers HART mode that inserts a 250 ohm resistor in mA measure and source for compatibility with HART instrumentation

Fluke - 729 Automatic Pressure Calibrator

  • Automatic pressure generation and regulation to 300 psi
  • Easily document the process using onboard test templates
  • Automatic internal fine-pressure adjustment
  • Measure, source and simulate 4 to 20 mA signals
  • 24V loop power for powering transmitters for tests
  • Bright dual/triple-channel color graphical display
  • HART communication for testing HART smart transmitters
  • Built-in leak testing for verifying test setups for leakage
  • Rugged portable design with standard 3-year warranty
  • Fluke Connect® App compatibility
  • Measure temperature with optional 720RTD probe
  • Measure Vdc for testing 1 V dc to 5 V dc output transmitters
  • Compatible with 700 Series and 750 Series pressure modules
  • Upload documented test results to DPCTrack2™ Calibration Management Software
  • Innovative semi-rigid carrying case designed for field work

Fluke - 750P Series Pressure Modules

The 750P Series Pressure Modules are the ideal pressure modules to enable gage, differential and absolute pressure measurement with Fluke 750 and 740 series DPCs and 725, 726 MPCs to measure pressure.

  • Up to 0.01% reference uncertainty
  • 6-month and 1-year specifications
  • Temperature compensated 0°C to 50°C
  • Digital communication to calibrators, no analog losses or errors
  • Broad selection of ranges
  • Gage, differential, dual range, absolute and vacuum measurement models
  • Eight (8) Intrinsically Safe models that are certified to:
    • NEC-500: Class I Div 1, Groups A-D, Ga
    • ATEX: II 1 G Ex ia IIC T4 Ga
    • IECEx: Ex ia IIC T4 Ga
    • *All certifications: Ta = -10 °C to +50 °C

Fluke - 753 Documenting Process Calibrator

  • Full-featured documenting process calibrator for calibrating and troubleshooting
  • Measures volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Sources and simulate volts, mA, pressure, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

Fluke - 754 Documenting Process Calibrator-HART

  • Full-featured documenting process calibrator with HART communication for calibrating and troubleshooting HART instrumentation.
  • Measures volts, mA,TDs, thermocouples, frequency, and ohms to test sensors, transmitters and more
  • Sources/simulates volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Powers transmitters during test using loop supply with simultaneous mA measurement

Fluke - P5510-2700G, P5513-2700G Pneumatic Pressure Calibrators

  • Best-in-class accuracy of 0.02% full scale for each 2700G Reference Gauge
  • Expand lower range capability with additional 2700G Reference Gauges
  • Adaptors to provide hand tight connection to common NPT, BSP, and metric fitting types
  • Included reference gauges are battery operated and capable of using line power too
  • Portable with a sturdy carrying case
  • Best-in-class accuracy of 0.02% full scale for each 2700G Reference Gauge
  • Expand lower range capability with additional 2700G Reference Gauges
  • Adaptors to provide hand tight connection to common NPT, BSP, and metric fitting types
  • Included reference gauges are battery operated and capable of using line power too
  • Portable with a sturdy carrying case
P5510-2700G specific features:
  • Built-in pump for generating both vacuum and positive pressure
  • Pressure range 0 to 300 psi 2 MPa (300 psi)
  • Vacuum range 0 to 27 inHg (915 mbar)
  • Up to three 2700G Reference Pressure gauges
  • Fine needle vent valve for small adjustment and venting of pressure
  • No external bottle
  • Manually operated
P5513-2700G specific features
  • Pressure range 0 to 3000 psi (210 bar)
  • Vacuum range 0 to 24 inHg (800 mbar)
  • Up to three 2700G Reference Pressure gauges
  • Built-in screw press for fine pressure adjustments
  • Clean testing of process critical instrumentation
  • Requires pressure source (i.e. nitrogen bottle) for operation

Fluke - P5551 Pointer Remover/Punch

This tool is designed to quickly remove and consistently refit the pointer of a pressure gauge.

Fluke Calibration - 6531, 6532 E-DWT Electronic Deadweight Tester Kits

A powerful, complete hydraulic pressure calibration system to cover a wide workload
Fluke Calibration improved the hydraulic pressure calibration process with the introduction of E-DWT-H electronic deadweight tester. E-DWT-H is an electronic calibrator designed to deliver traditional hydraulic deadweight tester performance with digital measurement features and convenience. Some improvements offered by E-DWT-H include:
  • No weights to load and unload, transport or send out for calibration
  • Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
  • No piston-cylinder changes
  • No significant sensitivity to level or vibration
  • Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
  • Operates in any unit of measure, switching easily from one unit to the next
The E-DWT-H is at home in metrology and calibration labs, on the production floor or in the field. It can operate with a wide selection of test mediums, including Sebacate calibration fluid, mineral oil, water and other liquids. ± 0.02 % of reading total one-year measurement uncertainty rivals the best laboratory deadweight testers.

Fluke Calibration - E-DWT Electronic Deadweight Tester

All the features you expect in today’s state-of-the-art instruments, including:
Accuracy and performance
  • One-year measurement uncertainty is ± 0.02% of reading from 10% to 100% with one Q-RPT, and from 1% to 100% with two Q-RPTs
  • Low torque variable volume allows for pressure generation up to 200 MPa (30,000 psi) with minimal physical effort
  • Separate fine adjustment tool for maximum, superfine control resolution
  • User defined resolution and ready limits enable user to optimize performance based on DUT specifications
  • High pressure isolation valve and pressure relief valve protect the low pressure reference transducer from over pressure when high pressure reference transducer is active
Ease of use
  • AutoRange feature optimizes measurement and safety features for the specific range of the instrument being calibrated
  • Simple rezeroing while vented at atmospheric pressure
  • Simple, objective pressure “ready/not ready indicator with user adjustable criteria to ensure repeatable results among operators
  • Not dependent on local gravity or ambient temperature
  • Sets and reads any pressure value directly in any unit of measure, without moving weights
  • Built-in priming system to fill system with test fluid and purge unwanted air to assure smooth operation
  • Optional foot switch accessory allows hands-free data collection when running AutoTests
Portability
  • Rechargeable battery pack option for eight hours of field operation
  • Everything to set, adjust and read pressure in one compact, transportable package
  • Optional shipping/carrying case with handles and wheels allows for easy transport to field application
  • Proven rugged and weatherproof design with room for accessories.
Automation
  • RS232 interface allows for real time automated data collection and customized report generation using COMPASS® for Pressure calibration software

Fluke Calibration - P3000 Pneumatic Deadweight Testers

  • 0.015% of reading accuracy standard (0.008% optional)
  • 1-30 inHg vacuum (0.03-1 bar vacuum)
  • 3-500 psi (0.2-35 bar) pressure
  • inH2O and mbar ranges available
  • Series 3 non-magnetic stainless steel weights
  • Units can be trimmed to local gravity FOC

Fluke Calibration - P3100 Hydraulic Deadweight Testers

  • Pressure ranges to 60,000 psi (4000 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston format
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC

Fluke Calibration - P3200 Hydraulic Deadweight Tester

  • Pressure ranges to 10,000 psi (700 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston formats
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC

Fluke Calibration - P3800 Series Hydraulic Deadweight Tester

  • Pressure ranges to 60,000 psi (4000 bar)
  • Select from two accuracy classes; 0.02% or 0.015% of reading
  • Includes hand pump and intensifier for generating high pressures
  • Tungsten carbide piston and cylinder provides long term stability and durability
  • Mass set can be trimmed to local gravity FOC

Fluke Calibration - P5510 Pneumatic Comparison Test Pump

Dual pressure/vacuum capability
Bench mount design
Built-in handpump as pressure/vacuum source
High quality needle valve for fine control
Test port adapters that require no PTFE tape or wrenches

Fluke Calibration - P5513 Pneumatic Comparison Test Pump

  • High pressure pneumatic operation
  • Screw press for fine pressure adjustments
  • High quality needle valves for fine control
  • Test port adapters which require no PTFE tape or wrenches
  • Sturdy carrying case with lid

Pages