Fluke Calibration - 4180/4181 Precision IR Calibrators
Product Overview:
The 4180 reaches temperatures from –15 °C to 120 °C and the 4181 has a temperature range from 35 °C to 500 °C. Uniformity is important in infrared temperature calibration work because an infrared thermometer will “see” as much as the entire target when placed at the appropriate calibration distance.
In addition, with accuracies as good as ±0.35 °C the 4180 Series can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.
IR Calibrator, 152 mm (6 in), -15°C to 120°C
Includes:
- 4180 IR calibrator
- Report of calibration (NVLAP accredited)
- Power cord
- User’s guide
- Documentation CD
- Target cover
- Serial cable
IR Calibrator, 152 mm (6 in), 35°C to 500°C
Includes:
- 4181 IR calibrator
- Report of calibration (NVLAP accredited)
- Power cord
- User’s guide
- Documentation CD
- Target cover
- Serial cable
Specifications | 4180 | 4181 |
Temperature range (@ 23°C ambient, 0.95 emissivity) | –15°C to 120°C | 35°C to 500°C |
Display accuracy1 |
±0.40°C at –15°C ±0.40°C at 0°C ±0.50°C at 50°C ±0.50°C at 100°C ±0.55°C at 120°C |
±0.35°C at 35°C ±0.50°C at 100°C ±0.70°C at 200°C ±1.20°C at 350°C ±1.60°C at 500°C |
Stability |
±0.10°C at –15°C ±0.05°C at 0°C ±0.10°C at 120°C |
±0.05°C at 35°C ±0.20°C at 200°C ±0.40°C at 500°C |
Uniformity (5.0 in dia of center of target)2 |
±0.15°C at –15°C ±0.10°C at 0°C ±0.25°C at 120°C |
±0.10°C at 35°C ±0.50°C at 250°C ±1.00°C at 500°C |
Uniformity (2.0 in dia of center of target)2 |
±0.10°C at -15°C ±0.10°C at 0°C ±0.20°C at 120°C |
±0.10°C at 35°C ±0.25°C at 250°C ±0.50°C at 500°C |
Heating time |
15 min: –15°C to 120°C 14 min: 23°C to 120°C |
20 min: 35°C to 500°C |
Cooling time |
15 min: 120°C to 23°C 20 min: 23°C to –15°C |
100 min: 500°C to 35°C 40 min: 500°C to 100°C |
Stabilization time | 10 minutes | 10 minutes |
Nominal emissivity3 | 0.95 | 0.95 |
Thermometer emissivity compensation | 0.9 to 1.0 | 0.9 to 1.0 |
Target diameter | 152.4 mm (6 in) | 152.4 mm (6 in) |
Computer interface | RS-232 | RS-232 |
Power |
115 V AC (±10%), 6.3 A, 50/60 Hz, 630 W 230 V AC (±10%), 3.15 A, 50/60 Hz, 630 W |
115 V AC (±10%), 10 A, 50/60 Hz, 1000 W 230 V AC (±10%), 5 A, 50/60 Hz, 1000 W |
Fuse(s) |
115 V AC 6.3 A, 250 V, slow blow 230 V AC 3.15 A, 250 V, T |
115 V AC 10 A, 250 V, fast blow 230 V AC 5 A, 250 V, F |
Size (H x W x D) |
356 x 241 x 216 mm (14 x 9.5 x 8.5 in) |
356 x 241 x 216 mm (14 x 9.5 x 8.5 in) |
Weight | 9.1 kg (20 lb) | 9.5 kg (21 lb) |
1. For 8 um to 14 um spectral band thermometers with emissivity set between 0.9 and 1.0 2. The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the targer will measure the same temperature. 3. The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties. |
More Product Information
-
Precision multifunction process calibrator designed specifically for the process industry
-
Delivers precise measurement and calibration source performance with accuracies of 0.01%.
-
Stores up to eight calibration results in memory for later analysis
-
Offers HART mode that inserts a 250 ohm resistor in mA measure and source for compatibility with HART instrumentation
The DewK measures temperature to ±0.125 °C and humidity to ±1.5% on two channels, and displays it on a big, clear screen. Ethernet, wireless (optional), or RS-232 will allow you to network as many DewKs as you’d like. And the Log Ware III software will allow real-time logging of multiple DewKs, data storage to your computer and seamless integration with MET/CAL® software.
-
Superior accuracy
-
Network enabled
-
Powerful logging and analysis tools
-
Two interchangeable calibrated sensors
-
Huge memory
-
Upgraded software
-
Calibrate up to four tri-clamp sanitary sensors at the same time
-
Wide temperature ranges cover most process applications:
-
6109A: 35 °C to 250 °C
-
7109A: –25 °C to 140 °C
-
-
Excellent display accuracy of ±0.1 °C provides 4:1 test uncertainty ratio (TUR) for critical applications
-
Easy to transport up stairs and across catwalks
-
Stainless steel casing withstands harsh sterilizing chemicals and is rust proof
-
Easy to use and maintain
-
Global Fluke support and service
-
Highly accurate, full-featured , easy-to-use single function RTD temperature calibrator
-
Measures and simulates 13 different RTD types and resistance
-
Measures 4 to 20 mA signals while simultaneously sourcing a temperature signal
-
Comes with a magnetic hanging tool designed in for convenient hands-free operation
-
Features configurable 0% and 100% source settings for quick 25% linearity checks
-
mA precision loop calibrator with best-in-class accuracy at 0.01% reading
-
Provides intuitive user interface with quick-set rotary encoder knob for fast setup
-
Includes built in selectable 250 Ω resistor for HART communication
-
Features 24 V DC loop power with mA Measure Mode (-25% to 125%)
-
Requires only simple two wire connection for all measurements
The 721Ex can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).
- Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)
- Ideal for gas flow calibration (custody transfer) applications
- Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
- Pt100 RTD input for temperature measurement, (probe optional)
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units
- Large backlit graphic display can display up to three inputs simultaneously
- Store five instrument setups for recall and use
-
6.5 digit resolution
-
Basic V DC accuracy of up to 0.0035%
-
Dual display
-
100 μA to 10 A current range, with up to 100 pA resolution
-
Wide ohms range from 100 Ω to 100 MΩ with up to 100 μΩ resolution
-
2 x 4 ohms 4-wire measurement technique
-
Measure frequency and period
-
Fluke 45 and Agilent 34401A emulation
-
Graphical display
-
Trendplot™ paperless recorder mode, statistics, histogram
-
CAT I 1000 V, CAT II 600 V
-
Three-year warranty
The 1586A Super-DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, DC voltage, DC current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab.
- Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance
-
Best-in-class temperature measurement accuracy
- PRTs ±0.005 °C (using external DAQ-STAQ Multiplexer)
- Thermocouples: ±0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ±0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for DC voltage, DC current, and resistance
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurment accuracy
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Mx + B scaling and channel offset zero function
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
-
mA precision loop calibrator that communicates with and tests HART smart instruments
-
Features best-in-class accuracy at 0.01% reading
-
Provides intuitive user interface with Quick-Set knob for fast setup
-
Includes built in selectable 250 Ω resistor for HART communication
-
Features 24 V DC loop power with mA measure mode (-25% to 125%)
Fluke Corporation
Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.
From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.
Fluke has achieved the number one or number two position in every market in which it competes. The Fluke brand has a reputation for portability, ruggedness, safety, ease of use and rigid standards of quality.
Contact Details
Fluke Corporation Headquarters
6920 Seaway Blvd., Everett, WA 98203
Mailing address: PO Box 9090, Everett, Washington 98206-9090
Phone: 1-425-347-6100
Technical Support Email: fluke-info@fluke.com
Building infrastructure | |
HVAC tools | Indoor air quality testing |
Laser distance meters | Laser levels |
Wire tracers |
Condition monitoring | |
Power monitoring | Vibration monitoring |
Connected reliability | |
Suite for Maximo |
Mechanical maintenance | |
Laser alignment | Vibration analysis |
Network cable testers | |
Copper testers | Fiber optic testers |
Industrial ethernet testers |
Precision measurement | |
Bench instruments | Data acquisition |
Temperature measurement | |
Contact thermometers | IR thermometers |
Thermal Imaging | |
IR Windows | Thermal cameras |