Fluke - 724 Temperature Calibrator

Product Overview:

  • A powerful, easy-to-use calibrator that measures and sources functions to test and calibrate most temperature instruments
  • Displays input and output simultaneously on the easy-to-read dual display
  • Measures RTDs, thermocouples, ohms, and volts to test sensors and transmitters
  • Source/simulates thermocouples, RTDs, volts, and ohms to calibrate transmitters

More

Fluke 724 Temperature Calibrator offers everything you need to troubleshoot and calibrate temperature

The Fluke 724 is powerful yet easy-to-use temperature calibrator that sources and measures 10 thermocouple types, and 7 RTD types, plus volts and ohms. It also measures mA while supplying loop power. You can use it to test and calibrate almost any temperature instrument so you only have to carry one tool to expertly test all the temperature sensors and transmitters in your plant.

The Fluke 724 even handles high-speed pulsed RTD circuits and provides loop power. The dual-line measure/source display lets you source temperature and view loop current at the same time. And with its simple, "no menus controls, you'll be able to get all your testing done faster.

Other useful features:

  • A bright backlight to enable you to work in poor light
  • Large battery capacity with four AA alkaline batteries
  • Easy to access battery door for quick changes

Other useful features:

  • Performs fast linearity tests with 25% and 100% steps
  • Executes remote tests with auto step and auto ramp
  • Powers transmitters during test using loop power supply with simultaneous mA measurement
  • Features a compact, streamlined shape that makes it easy to carry
  • Offers a rugged, reliable design that stands up to field use

Fluke 724 Temperature Calibrator

Includes:

  • AC70A Test Clips
  • One pair of stackable test leads
  • TL75 Test Leads
  • CE and CSA Markings
  • Manuals in English, French, German, Spanish, Italian, Portugese, Korean, Chinese and Japanese
  • Users manuals on CD-ROM
  • NIST- traceable calibration report and data
Measurement Accuracy
Voltage DC 30.000 V 0.02% + 2 counts (upper display)
20.000 V 0.02% + 2 counts (lower display)
100.00 mV 0.02% + 2 counts
-10.00 mV to 75.00 mV 0.025% + 1 count (via TC connector)
Current DC 24.000 mA 0.02% + 2 counts
Resistance 0.0 to 400.0 Ω 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
401 to 1500 Ω 0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
1500 to 3200 Ω 1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
Source Accuracy
Voltage DC 100.00 mV 0.02% + 2 counts
10.000 V 0.02% + 2 counts
-10.00 mV to 75.00 mV 0.025 % + 1 count (via TC connector)
Resistance 15.0 to 400.0 Ω 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω 0.5 Ω (excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω 1 Ω (excitation current 0.05 to 0.4 mA)
RTDs and Thermocouples
Measure accuracy NI-120 0.2°C
PT-100 (385) 0.33°C
PT-100 (393) 0.3°C
PT-100 (JIS) 0.3°C
PT-200 (385) 0.2°C
PT-500 (385) 0.3°C
PT-1000 (385) 0.2°C
Resolution 0.1°C
J 0.7°C
K 0.8°C
T 0.8°C
E 0.7°C
R 1.8°C
S 1.5°C
B 1.4°C
L 0.7°C
U 0.75°C
N 0.9°C
Resolution J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
XK 0.6°C
BP 1.2°C
Source accuracy NI-120 0.2°C
PT-100 (385) 0.33°C
PT-100 (393) 0.3°C
PT-100 (JIS) 0.3°C
PT-200 (385) 0.2°C
PT-500 (385) 0.3°C
PT-1000 (385) 0.2°C
Resolution 0.1°C
Accuracy stated for 4-wire measurement.
J 0.7°C
K 0.8°C
T 0.8°C
E 0.7°C
R 1.4°C
S 1.5°C
B 1.4°C
L 0.7°C
U 0.75°C
N 0.9°C
Resolution J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
XK 0.6°C
BP 1.2°C
Specifications
Ramp functions Source functions Voltage, current, resistance, frequency, temperature
Ramps Slow ramp, Fast ramp, 25% step-ramp
Loop power function Voltage 24 V
Accuracy 10%
Maximum current 22 mA, short circuit protected
Step functions Source functions Voltage, current, resistance, frequency, temperature
Steps 25% of range, 100% of range
Environmental Specifications
Operating temperature -10°C to 55°C
Storage temperature -20°C to 71°C
Humidity (without condensation) 90% 10°C to 30°C
75% 30°C to 40°C
45% 40°C to 50°C
35% 50°C to 55°C
Safety Specifications
Safety rating CSA C22.2 No. 1010.1:1992
EMC EN50082-1:1992 and EN55022:1994 Class B
Mechanical and General Specifications
Size 96 x 200 x 47 mm
Weight 650 g
Batteries Four AA alkaline batteries
Warranty Three years
Battery life 25 hours typical
Shock and vibration Random, 2 G, 5-500 Hz

More Product Information

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.05°C (±0.09°F) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -80 °C to 300 °C ( -112 °F to 572 °F)
  • Provides user-configurable temperature with Trend/Stability indicator
  • Displays temperature in °C or °F

  • Intrinsically-safe, battery operated, portable reference thermometer
  • Provides accuracy of ±0.05°C (±0.09°F) over full range
  • Features intrinsically-safe operation (ATEX and IECEx compliant)
  • Measures -50 °C to 160 °C (-58 °F to 320 °F)
  • Provides user-configurable temperature with Trend/Stability indicator
  • Displays temperature in °C or °F

Fluke 789 Temperature Kit features:

  • Unique new wireless measurement logging capability
  • Temperature measurement from -200 °C to 1372 °C using the t3000 FC
  • 24 V Loop power supply
  • HART mode setting with loop power (adds 250 ohm resistor)
  • 100% larger dual display
  • 1200 ohm drive capability on mA source
  • Enhanced backlight with two brightness settings
  • 0% to 100% mA Span Check buttons to toggle between 4 and 20 mA
  • Infrared I/O serial port compatible with
  • FlukeView® Forms Software Version 2.1
  • Externally accessible fuses for easy replacement

These 787 features are also included in the 789:

  • DMM designed to meet 1000 volt IEC 1010 CAT III standards
  • Precision 1000 V, 440 mA True-RMS digital multimeter
  • Frequency measurement to 20 kHz
  • Min/Max/Average/Hold/Relative modes
  • Diode test and continuity beeper
  • Simultaneous mA and% of scale readout
  • 20 mA DC current source/loop calibrator/ simulator
  • Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
  • Externally accessible battery for easy battery changes

  • Backlit dual display of humidity and temperature
  • Measures dew point and wet bulb temperatures
  • 99 record storage capacity
  • Ergonomic design with belt clip and protective holster
  • Quick-response capacitance sensor
  • Compact and lightweight (188 g /6.6 oz)
  • Temperature range from -20 °C to 60 °C (-4 °F to 140 °F)
  • Relative humidity from 5% to 95%
  • Min/Max/Avg Data hold
  • Low battery indicator

The Fluke t3000 FC Wireless K-Type Temperature Module wirelessly relays measurements to other Fluke Connect® enabled master units, listed below:
  • Fluke 3000 FC DMM
  • Fluke Ti200/300/400 Infrared Camera
  • PC via optional pc3000 FC Adapter
  • Fluke Connect Mobile app
With the Fluke t3000 FC Wireless K-Type Temperature Module you can:
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings

  • Single Input digital thermometer with data logging for lab, QA, process calibration, food safety and HVAC
  • Logs up to 500 points of data at user adjustable recording intervals
  • Measures J, K, T, E, R, S, and N-type thermocouples
  • Presents results in °C, °F, or Kelvin (K) on a large backlit display
  • Provides a recall function to easily review logged data

  • High temperature infrared thermometer that measures from -30°C to 900°C (-22°F to 1652°F)
  • Offers an ultra-high 60:1 distance-to-spot ratio with dual laser sighting for fast, accurate targeting
  • Features a user-selectable multi-language interface
  • Displays the temperature plus MAX, MIN, DIF, AVG temperature
  • Provides adjustable emissivity and a predefined emissivity table

The 1586A Super-DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, DC voltage, DC current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab.

  • Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance
  • Best-in-class temperature measurement accuracy
    • PRTs ±0.005 °C (using external DAQ-STAQ Multiplexer)
    • Thermocouples: ±0.5 °C (using High-Capacity Module and internal CJC)
    • Thermistors: ±0.002 °C
  • Input channels: Up to 40 isolated universal inputs
  • Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
  • Selectable scan speed: Up to 10 channels per second
  • Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
  • Real-time color trending: Chart up to four channels simultaneously
  • 6 1/2 digit display resolution for DC voltage, DC current, and resistance
  • Current reversal minimizes thermoelectric effects, improving PRT/RTD measurment accuracy
  • Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
  • Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
  • Data security: Administrator and user profiles for protecting settings and ensuring test traceability
  • Mx + B scaling and channel offset zero function
  • Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded

  • Rugged, reliable basic True-RMS clamp meter
  • Measure AC current up to 400 A, AC/DC voltage to 600V
  • Measure resistance up to 4kΩ, continuity detection ≤ 30Ω
  • Additions from 323 Clamp: Temperature, Capacitance, Backlight

Fluke Corporation

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke has achieved the number one or number two position in every market in which it competes. The Fluke brand has a reputation for portability, ruggedness, safety, ease of use and rigid standards of quality.

Contact Details

Fluke Corporation Headquarters

6920 Seaway Blvd., Everett, WA 98203

Mailing address: PO Box 9090, Everett, Washington 98206-9090

Phone: 1-425-347-6100

Technical Support Email: fluke-info@fluke.com


Thermal Imaging
IR Windows Thermal cameras