Fluke - 717 Pressure Calibrator

Product Overview:

  • Measure pressure, 0.05% of full scale with internal sensor up to 5000 psi/345 bar sensor (5000G model)
  • Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24 V loop power
  • Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules
  • 1/8 NPT female pressure fitting
  • Compatible with non-corrosive Gases and liquids
  • Select eleven different engineering units
  • Zero, min, max, and hold functions
  • Calibrate P/I instruments with simultaneous pressure and current measurement
  • Pressure switch test function captures set, reset and Deadband values of a pressure switch
  • Error % calculation of mA measurements for quick pass-fail decisions
  • Long lasting battery life
  • Holster features test lead storage
  • Compatible with Toolpack magnetic hanging system
  • New switch test

More

The Fluke 717 Pressure Calibrator delivers outstanding performance, durability and reliability. The calibrator is compact, lightweight, and easy to carry. With a push button interface similar to the multifunction Fluke 750 Series Documenting Process Calibrators, the Fluke 717 Pressure Calibrator is easy to use. It is EMI tolerant, dust and splash resistant, and features a removable battery door for quick battery changes. The Fluke 717 Pressure Calibrator is compatible with Fluke 700Pxx differential, gauge and absolute pressure modules to increase functionality.

Fluke 717 1G Pressure Calibrator
1 to 1 psi, (-68.9 mbar to 68.9 mbar, -6.89 to 6.89 kPa)

Includes:

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST- traceable calibration report and data

Fluke 717 15G Pressure Calibrator
12 to 15 psi (-850 mbar to 1 bar, -85 to 103 kPa)


Fluke 717 30G Pressure Calibrator
12 to 30 psi (-850 mbar to 2 bar, -85 to 207 kPa)


Fluke 717 100G Pressure Calibrator
12 to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa)


Fluke 717 300G Pressure Calibrator
12 to 300 psi, (-850 mbar to 20 bar, -85 to 2068.4 kPa )


Fluke 717 500G Pressure Calibrator
0 to 500 psi, (0 mbar to 34.7 bar, 0 to 3447.4 kPa )


Fluke 717 1000G Pressure Calibrator
0 to 1000 psi, (0 mbar to 69 bar, 0 to 6894.8 kPa )


Fluke 717 1500G Pressure Calibrator
0 to 1500 psi, (0 bar to 103.4 bar, 0 to 10342 kPa )


Fluke 717 3000G Pressure Calibrator
0 to 3000 psi, (0 bar to 207 bar, 0 to 20684 kPa)


Fluke 717 5000G Pressure Calibrator
0 to 5000 psi, (0 bar to 345 bar, 0 to 34474 kPa)


Fluke 717 10,000G Pressure Calibrator
0 - 10,000 psi (0 to 690 bar, 0 to 69,000 kPa)

Measurement Accuracy
Pressure 717 Series
Measure Pressure (Internal sensor)
Accuracy 0.05% full scale
Functions Zero, min, max, hold, damp
  Note gasses / liquids (non-corrosive)
 
Fluke 717 1G
Range -1 to 1 psi, (-68.9 mbar to 68.9 mbar, -83 to 6.89 kPa)
Resolution 0.0001 psi, 0.001 mbar, 0.0001 kPa
Over pressure 5 x full scale
 
Fluke 717 30G
Range -12 to 30 psi, (-850 mbar to 2 bar, -83 to 206.84 kPa)
Resolution 0.001 psi, 0.1 mbar, 0.01 kPa
Over Pressure 2 x full scale
 
Fluke 717 100G
Range -12 to 100 psi, (-850 mbar to 7 bar, -83 to 689.48 kPa)
Resolution 0.01 psi, 0.1 mbar, 0.01 kPa
Over pressure 2 x full scale
 
Fluke 717 300G
Range -12 to 300 psi, (-850 mbar to 20 bar, -83 to 2068.42 kPa)
Resolution 0.01 psi, 1 mbar, 0.1 kPa
Over pressure 375 psi, 25 bar
 
Fluke 717 500G
Range 0 to 500 psi, (0 mbar to 34,7 bar, 0 to 3447.38 kPa)
Resolution 0.01 psi, 1 mbar, 0.1 kPa
Over pressure 2 x full scale
 
Fluke 717 1000G
Range 0 to 1000 psi, (0 mbar to 69 bar, 0 to 6894.76 kPa)
Resolution 0.1 psi, 1 mbar, 0.1 kPa
Over pressure 2 x full scale
 
Fluke 717 1500G
Range 0 to 1500 psi, (0 bar to 103.4 bar, 0 to 10342 kPa)
Resolution 0.1 psi, 0.01 mbar, 1 kPa
Over pressure 2 x full scale
 
Fluke 717 3000G
Range 0 to 3000 psi, (0 bar to 207 bar, 0 to 20684.27 kPa)
Resolution 0.1 psi, 0.01 bar, 1 kPa
Over pressure 2 x full scale
 
Fluke 717 5000G
Range 0 to 5000 psi, (0 bar to 345 bar, 0 to 34474 kPa)
Resolution 0.1 psi, 0.01 bar, 1 kPa
Over pressure 2 x full scale
 
Fluke 717 Series with Pressure Modules
Measure pressure (Via pressure module connector using optional Pressure Modules)
Range 29 pressure modules, 0-1 inH20 to 10,000 psi, 2.5 mbar to 700 bar ranges. Over pressure per pressure module specs
Resolution Per pressure module specs
Accuracy Per pressure module specs
Functions Zero, min, max, hold, damp
Current Range 0 to 24 mA (-25% to 125%)
Resolution 0.001 mA
Accuracy 0.015% + 2 counts
Specifications
Loop power Range 24 V DC
Accuracy ±10%
  Drive; 20 mA into 1000 ohms for battery > 6.8 V; 700 W for battery 5.8 to 6.8 V
Display Clear 5 digit LCD
Environmental Specifications
Operating temperature -10°C to 55°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 95% (10°C to 30°C)
75% (30°C to 40°C)
45% (40°C to 50°C)
35% (50°C to 55°C)
Operating altitude 3,000 M max
Safety Specifications
Safety CSA C22.2 No. 1010.11992
Mechanical and General Specifications
Size (L x W x H) 201 x 98 x 52 mm (7.93 x 3.86 x 2.06 in)
Weight 22 oz, approximately 600 G with holster
Warranty 3 years
Shock and vibration Random, 2 G, 5-500 Hz
1 m drop test
Battery type Single 9 V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline

More Product Information

  • Pressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device
  • Integrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field
  • Error % calculation for quicker pass/fail decision making in the field
  • Best in class mA accuracy of 0.015% for better measurement confidence and workload coverage
  • Min/Max/Hold to capture changing measurements
  • Switch test feature for quicker and more accurate pressure switch testing
  • New 1 and 300 psi pressure ranges mean fewer extra tools required
  • 1, 30, 100 & 300 psi ranges now available

  • Pressure calibrator with built-in electric pump for one-handed pressure calibration
  • Offers best-in-class pressure measurement uncertainty of 0.025%
  • Measures and sources mA with best in class 0.015% accuracy to test valves and I/Ps
  • Calibrates 30 psi and 100 psi pressure ranges
  • Features precision pressure adjustment vernier for easy and accurate pressure calibration

  • Unique integrated electric pump for one handed pressure calibration
  • Test pressure switches easily with easy-to-use switch test function
  • Precision pressure adjust vernier for easy and accurate pressure calibration
  • Ideal accuracy and performance (0.025%) for reference class transmitter calibration
  • 30 psi, 150 psi and 300 psi pressure ranges
  • Programmable pressure calibrator pump limit:
    • Eliminates over-pressurization
    • Allows the user to program target pressures for pumping
  • Extended pressure measurement range with any of 29 750P Pressure Modules
  • Pump cleanout ports reduce pump failures from moisture and fluid damage
  • Fluid trap included with the unit to mitigate chance of fluid damage in at-risk applications
  • Precision temperature measurement with optional RTD probe

  • Automatic pressure generation and regulation to 300 psi
  • Easily document the process using onboard test templates
  • Automatic internal fine-pressure adjustment
  • Measure, source and simulate 4 to 20 mA signals
  • 24V loop power for powering transmitters for tests
  • Bright dual/triple-channel color graphical display
  • HART communication for testing HART smart transmitters
  • Built-in leak testing for verifying test setups for leakage
  • Rugged portable design with standard 3-year warranty
  • Fluke Connect® App compatibility
  • Measure temperature with optional 720RTD probe
  • Measure Vdc for testing 1 V dc to 5 V dc output transmitters
  • Compatible with 700 Series and 750 Series pressure modules
  • Upload documented test results to DPCTrack2™ Calibration Management Software
  • Innovative semi-rigid carrying case designed for field work

The 3130-G2M Portable Pneumatic Pressure Calibrator is ideal for calibrating pressure transmitters, transducers, gauges and similar devices. The 3130-G2M contains everything you need to generate, control and measure pressure, as well as read the output of the device under test (DUT).
Features
  • Measure and generate pressures from vacuum to 2 MPa (300 psi, 20 bar)
  • Internal pump can generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar)
  • Supply pressure connection allowing the use of external gas supply up to 2 MPa (300 psi, 20 bar)
  • Includes variable volume for fine adjustment of pressures
  • Pressure measurement accuracy of 0.025% reading ±0.01% FS
  • Electrical measurement and 24 volt supply for close looped calibrations
  • Measure or generate 4 to 20 mA
  • Measure 0 to 30 V DC
  • Powered by internal, high capacity, NiMH battery or universal ac mains adapter
  • Compatible with Fluke 700P Pressure Modules

  • Rugged, high-quality pressure gauge calibrator for fast and accurate test results
  • Delivers precision pressure measurements in 23 ranges from ±10 inH2O/20 mbar to 10,000 psi/690 bar
  • Delivers high accuracy—0.05% total measurement uncertainty for one year
  • Provides bright backlit display for easy viewing
  • Features rugged, durable design with protective holster

The 721Ex can be configured by selecting either a 16 PSI (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).

  • Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)
  • Ideal for gas flow calibration (custody transfer) applications
  • Two isolated, stainless steel, pressure sensors with 0.025 % accuracy
  • Pt100 RTD input for temperature measurement, (probe optional)
  • Switch test on both pressure inputs
  • Pressure displayed in the user’s choice of 19 engineering units
  • Large backlit graphic display can display up to three inputs simultaneously
  • Store five instrument setups for recall and use

  • ATEX II 1G Ex ia IIC T4 Compliant.
  • Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.
  • 30, 100, and 300 psi ranges (2, 7, and 20 bar)
  • Pressure measurement to 0.05% of full span, using an internal pressure sensor.
  • Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules.
  • Wide range of selectable measurement units for pressure.
  • Current measurement with 0.02% accuracy and 0.001 mA resolution.
  • Pressure switch test function.
  • Min-Max Hold functions.
  • Compact size and weight.
  • Simple, push-button user interface.
  • Rugged and reliable, ideal for field use.

  • Precision pressure calibrator with dual isolated sensors for gas flow calibration (custody transfer) applications
  • Features two isolated, stainless steel, pressure sensors with 0.025% accuracy
  • Includes Pt100 RTD input for temperature measurement (probe optional)
  • Measures 4 to 20 mA signals
  • Provides internal 24 V loop power supply to power a transmitter under test

Fluke Corporation

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke has achieved the number one or number two position in every market in which it competes. The Fluke brand has a reputation for portability, ruggedness, safety, ease of use and rigid standards of quality.

Contact Details

Fluke Corporation Headquarters

6920 Seaway Blvd., Everett, WA 98203

Mailing address: PO Box 9090, Everett, Washington 98206-9090

Phone: 1-425-347-6100

Technical Support Email: fluke-info@fluke.com


Thermal Imaging
IR Windows Thermal cameras