Fluke - 117 Electrician's Multimeter with Non-Contact Voltage

Product Overview:

  • Non-contact voltage detection
  • AutoVolt automatic AC/DC voltage selection
  • Prevent false readings caused by ghost voltage with selectable low-impedance mode

More

The Fluke 117 Electricians Multimeter includes integrated non-contact voltage detection and Auto Volts and LoZ functions to help get the job done faster and prevent false readings caused by ghost voltage. It is a compact true-rms meter for demanding applications like commercial buildings, hospitals, and schools.

The Fluke 117 provides Min/Max/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.

Other useful features:

  • Features true-rms capabilities for accurate measurements on non-linear loads
  • Accurate, easy-to-use multimeter with integrated VoltAlert™ technology for fast, go/no go non-contact voltage detection
  • Features AutoVolt automatic AC/DC voltage selection
  • Provides low input impedance to help prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas
  • Measures 10 A (20 A overload for 30-seconds)
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with an holster with probe holders for easy storage
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation
  • CAT III 600 V safety rated
  • A large white LED backlight to improve measurement visibility in poorly lit areas

Fluke 117 Electrician's Digital Multimeter with Non-Contact Voltage

Includes:

  • 4 mm silicone test lead set
  • Holster
  • User manual
Specifications
Maximum voltage between any terminal and earth ground 600 V
Safety IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Battery type 9 volt Alkaline, IEC 6LR61
Battery life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
Diode test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps Range/resolution

6.000 A / 0.001 A   10.00 A / 0.01 A

Accuracy 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g
Warranty 3 years

More Product Information

  • Contact and non-contact thermometer in one
  • Measures temperatures from -40°C to 800°C (-40°F to 1472°F) accurate to +1.0°C or +1.0% of reading (whichever is greater)
  • Features rugged, ergonomic design that stands up to tough industrial, electrical, and mechanical environments.
  • Offers a distance-to-spot ratio of 50:1
  • Works with most K-type thermocouples

  • Contact and non-contact IR thermometer for measuring up close or at a distance, without a ladder
  • Measures temperature from -40°C to 550° C (-40°F to 1022°F)
  • Works with all standard mini-connector type K thermocouples
  • Provides single-point laser sighting
  • Allows easy emissivity adjustment for measuring pipes and other shiny surfaces more accurately

  • Two-in-one IR and contact thermometer with a 30:1 distance-to-spot ratio
  • Measures temperatures from -40°C to 650°C (40°F to 1202°F)
  • Makes it easy to access advanced features with the soft-key buttons and graphical display
  • Features rugged, ergonomic design that stands up to tough industrial, electrical, and mechanical environments
  • Works with most K-type thermocouples

  • Large display
  • Backlight for work in dim areas
  • Min / Max to record signal fluctuations
  • Ergonomic overmolded housing with integrated probe holders
  • Free your hands with the optional TPAK magnetic hanger
  • Auto and Manual ranging
  • Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards
The 77 IV replaces the 77. Move up to superior utility and safety today.

  • VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity*
  • True RMS for accurate AC measurements on non-linear loads
  • A large backlit display allows for easy visibility in low-lit areas
  • Record signal fluctuations using the Min/Max function
  • Diode test for testing general-purpose germanium, silicon, and power diodes
  • Integral holster with probe holders for easy storage
  • Auto and Manual ranging for added user functionality
  • The optional TPAK magnetic hanger allows the user hands-free flexibility

  • Ideal Digital Multimeter for “go/no-go” testing
  • Features AutoVolt automatic AC/DC voltage selection
  • Includes low input impedance to help prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas
  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average with elapsed time to record signal fluctuations

  • Identify complex signal problems fast
  • Supports accurate measurements on VFDs using a low-pass filter
  • Captures intermittents as fast as 250 µS with Peak Capture

  • DMM and a loop calibrator in one rugged, handheld tool
  • Provides a precision 1000 V, 440 mA True-RMS digital multimeter designed to meet 1000 volt IEC 1010 CAT III standards
  • Features a clear LCD with backlight; 4,000 counts (30,000 counts for DC current)
  • Performs frequency measurements to 20 kHz

  • 0.1% DC accuracy
  • Current measurements up to 10 A, 20 A for up to 30 seconds
  • Millisecond pulse width measurements for fuel injectors
  • Optional magnetic hanger allows meter to attach to the vehicle and free your hands for other tasks
  • Min/Max/Average recording with Min/Max Alert to capture variations automatically
  • Peak Min/Max to record transients as fast as 250 μs
  • Relative mode to remove test lead resistance from low ohms measurements
  • Auto and manual ranging for maximum flexibility
  • Autohold™ to capture stable readings with only one touch of the leads
  • Large display digits and two-level bright white backlight for increased visibility
  • Analog bargraph to track changing or unstable signals
  • Input Alert provides audible warning against wrong use of input jacks
  • Access door for fast battery changes without opening up the case
  • "Classic" design that fits your hand with new removable holster, built-in test lead and probe storage
  • 10 meg ohm input impedance won’t damage computer circuits
  • Limited lifetime warranty

Fluke Corporation

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke has achieved the number one or number two position in every market in which it competes. The Fluke brand has a reputation for portability, ruggedness, safety, ease of use and rigid standards of quality.

Contact Details

Fluke Corporation Headquarters

6920 Seaway Blvd., Everett, WA 98203

Mailing address: PO Box 9090, Everett, Washington 98206-9090

Phone: 1-425-347-6100

Technical Support Email: fluke-info@fluke.com


Thermal Imaging
IR Windows Thermal cameras