Fluke - 789 FC ProcessMeter™ and Temperature Kit
Product Overview:
Fluke 789 Temperature Kit features:
- Unique new wireless measurement logging capability
- Temperature measurement from -200 °C to 1372 °C using the t3000 FC
- 24 V Loop power supply
- HART mode setting with loop power (adds 250 ohm resistor)
- 100% larger dual display
- 1200 ohm drive capability on mA source
- Enhanced backlight with two brightness settings
- 0% to 100% mA Span Check buttons to toggle between 4 and 20 mA
- Infrared I/O serial port compatible with
- FlukeView® Forms Software Version 2.1
- Externally accessible fuses for easy replacement
These 787 features are also included in the 789:
- DMM designed to meet 1000 volt IEC 1010 CAT III standards
- Precision 1000 V, 440 mA True-RMS digital multimeter
- Frequency measurement to 20 kHz
- Min/Max/Average/Hold/Relative modes
- Diode test and continuity beeper
- Simultaneous mA and% of scale readout
- 20 mA DC current source/loop calibrator/ simulator
- Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
- Externally accessible battery for easy battery changes
Fluke-789 FC/t3000
Fluke 789 FC ProcessMeterTMand Temperature Kit
Includes:
- Fluke 789 ProcessMeter
- Fluke t3000 FC Wireless K-Type Temperature Module
- Fluke ir3000 FC Connector
- TL71 Premium Test Lead Set
- AC72 Alligator Clips
- Four (4) AA alkaline batteries (installed)
- Users' manual
- Quick reference guide
Fluke 789 ProcessMeter™ with Fluke Connect™
Specifications | ||
Current measurement | Range | 0-1 A AC or DC |
Resolution | 1 mA | |
Accuracy | 0.2% + 2 LSD (DC) | |
Range | 0-30 mA | |
Resolution | 0.001 mA | |
Accuracy | 0.05% + 2 lSD | |
Current sourcing | Range | 0-20 mA or 4-20 mA |
Resolution | 0.05% of span | |
Drive capability | 24 V Compliance or 1200 Ω @ 20 mA | |
Frequency | to 19.999 kHz, 0.005% + 1 LSD | |
Continuity | Beeps for resistance < 100 Ω | |
Voltage measurement | Range | 0-1000 V AC (true-rms) or DC |
Resolution | 0.1 mV to 1.0 V | |
Accuracy | 0.1% Rdg + 1 LSD (V DC) | |
Resistance measurement | to 40 MΩ, 0.2% + 1 LSD | |
Diode test | 2.0 V shoes diode voltage drop | |
Display current and % of span | Yes | |
Auto Step, Auto Ramp | Yes | |
Environmental Specifications | ||
Operating temperature | -20°C to 55°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) |
95% up to 30°C 75% up to 40°C 45% up to 50°C 35% up to 55°C |
|
Temperature coefficient | 0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C) | |
Safety Specifications | ||
Electrical safety | Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92 | |
Overvoltage category |
IEC 1010-1 CAT III 1000 V IEC 1010-1 CAT IV 600 V |
|
Maximum voltage | 1000 V RMS | |
Mechanical and General Specifications | ||
Size (H x W x L) | 50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in) | |
Weight | 610 g (1.6 lbs) | |
Batteries | 4 AA alkaline batteries | |
Warranty | 3 years | |
Battery life | 140 hours typical (measurement), 10 hours typical (sourcing 20 mA) | |
Shock and vibration |
Random, 2 g, 5-500 Hz 1 meter drop test |
Fluke t3000 FC Wireless K-Type Temperature Module
General Specifications | ||||
Range K-Type | -200°C to 1372°C | |||
Resolution | 0.1°C | |||
Accuracy | ±[0.5% + 0.5°C] counts | |||
Input terminals | K-type mini | |||
LCD w/backlight | 3 ½ digits | |||
Log rate/interval | 1 sec minimum/adjustable by PC | |||
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |||
Battery life | 400 hours | |||
Memory | Record up to 65,000 readings | |||
RF communications | 2.4 GHZ ISM Band | |||
RF communication range | Open air, unobstructed | Up to 20 m | ||
Obstructed, sheetrock wall | Up to 6.5 m | |||
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |||
Operating temperature | -10°C to +50°C | |||
Storage temperature | -40°C to +60°C | |||
Temperature coefficient | 0.01% of reading +0.03°C per °C | |||
Temperature scale | ITS-90 | |||
Operating humidity | 90% at 35°C, 75% at 40°C, 45% at 50°C | |||
Altitude | Operating | 2,000 m | ||
Storage | 12,000 m | |||
EMC | EN 61326-1:2006 | |||
Safety compliance | IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 | |||
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |||
Ingress Protection (IP) rating | IP42 | |||
Pollution Degree | 2 | |||
Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |||
Weight | .22 kg (8 oz) | |||
Not compatible with Fluke CNX test tools |
More Product Information
-
Ultimate troubleshooting tool for electricians and instrumentation professionals
-
Combines the functionality of a loop calibrator with the power of a precision 1000 V, 440 mA True-RMS digital multimeter
-
Optional IR3000FC module for wireless data logging capabilities via Fluke Connect® mobile App
-
Includes 24 V loop power supply
-
Features a very large dual display with enhanced two-level backlight brightness settings
-
20 mA dc current source/measure/simulate
-
Simultaneous mA and % of scale readout
-
DMM designed to meet 1000 volt IEC 61010 CAT III and 600 V CAT IV standards
-
Fluke Connect® compatibility for wireless data logging (with IR3000FC module*)
-
Precision 1000 V, 440 mA true-rms digital multimeter
-
Frequency measurement to 20 kHz
-
Min/Max/Average/Hold/Relative modes
-
Diode test and continuity beeper
-
Manual step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
-
Externally accessible battery for easy battery changes
-
DMM and a loop calibrator in one rugged, handheld tool
-
Provides a precision 1000 V, 440 mA True-RMS digital multimeter designed to meet 1000 volt IEC 1010 CAT III standards
-
Features a clear LCD with backlight; 4,000 counts (30,000 counts for DC current)
-
Performs frequency measurements to 20 kHz
-
A powerful, easy-to-use calibrator that measures and sources functions to test and calibrate most temperature instruments
-
Displays input and output simultaneously on the easy-to-read dual display
-
Measures RTDs, thermocouples, ohms, and volts to test sensors and transmitters
-
Source/simulates thermocouples, RTDs, volts, and ohms to calibrate transmitters
-
Backlit dual display of humidity and temperature
-
Measures dew point and wet bulb temperatures
-
99 record storage capacity
-
Ergonomic design with belt clip and protective holster
-
Quick-response capacitance sensor
-
Compact and lightweight (188 g /6.6 oz)
-
Temperature range from -20 °C to 60 °C (-4 °F to 140 °F)
-
Relative humidity from 5% to 95%
-
Min/Max/Avg Data hold
-
Low battery indicator
-
Fluke 3000 FC DMM
-
Fluke Ti200/300/400 Infrared Camera
-
PC via optional pc3000 FC Adapter
-
Fluke Connect Mobile app
-
Use as a standalone meter or as part of the system
-
Logging function for recording and saving up to 65,000 readings
-
Single Input digital thermometer with data logging for lab, QA, process calibration, food safety and HVAC
-
Logs up to 500 points of data at user adjustable recording intervals
-
Measures J, K, T, E, R, S, and N-type thermocouples
-
Presents results in °C, °F, or Kelvin (K) on a large backlit display
-
Provides a recall function to easily review logged data
-
High temperature infrared thermometer that measures from -30°C to 900°C (-22°F to 1652°F)
-
Offers an ultra-high 60:1 distance-to-spot ratio with dual laser sighting for fast, accurate targeting
-
Features a user-selectable multi-language interface
-
Displays the temperature plus MAX, MIN, DIF, AVG temperature
-
Provides adjustable emissivity and a predefined emissivity table
The 1586A Super-DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, DC voltage, DC current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for benchtop sensor calibration in the lab.
- Measure thermocouples, PRTs, thermistors, DC voltage, DC current, and resistance
-
Best-in-class temperature measurement accuracy
- PRTs ±0.005 °C (using external DAQ-STAQ Multiplexer)
- Thermocouples: ±0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ±0.002 °C
- Input channels: Up to 40 isolated universal inputs
- Flexible configuration: Internal High-Capacity Module and/or DAQ-STAQ Multiplexer
- Selectable scan speed: Up to 10 channels per second
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Real-time color trending: Chart up to four channels simultaneously
- 6 1/2 digit display resolution for DC voltage, DC current, and resistance
- Current reversal minimizes thermoelectric effects, improving PRT/RTD measurment accuracy
- Automated sensor calibration: Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Data storage: Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive. Transfer data to a PC using the USB drive or LAN connection and view data in Microsoft® Excel
- Data security: Administrator and user profiles for protecting settings and ensuring test traceability
- Mx + B scaling and channel offset zero function
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
Fluke Corporation
Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.
From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.
Fluke has achieved the number one or number two position in every market in which it competes. The Fluke brand has a reputation for portability, ruggedness, safety, ease of use and rigid standards of quality.
Contact Details
Fluke Corporation Headquarters
6920 Seaway Blvd., Everett, WA 98203
Mailing address: PO Box 9090, Everett, Washington 98206-9090
Phone: 1-425-347-6100
Technical Support Email: fluke-info@fluke.com
Building infrastructure | |
HVAC tools | Indoor air quality testing |
Laser distance meters | Laser levels |
Wire tracers |
Condition monitoring | |
Power monitoring | Vibration monitoring |
Connected reliability | |
Suite for Maximo |
Mechanical maintenance | |
Laser alignment | Vibration analysis |
Network cable testers | |
Copper testers | Fiber optic testers |
Industrial ethernet testers |
Precision measurement | |
Bench instruments | Data acquisition |
Temperature measurement | |
Contact thermometers | IR thermometers |
Thermal Imaging | |
IR Windows | Thermal cameras |